Modbus RTU vs Modbus TCP IP

Modbus RTU and Modbus TCP/IP are two different variants of the Modbus protocol, each designed for specific communication scenarios. Here are the key differences between Modbus RTU and Modbus TCP/IP:

  1. Communication Medium:
    • Modbus RTU: Modbus RTU uses serial communication, typically RS-485 or RS-232, as the physical layer. It transmits data in binary format over the serial connection.
    • Modbus TCP/IP: Modbus TCP/IP uses Ethernet as the communication medium. It operates over standard Ethernet networks using TCP/IP protocol stack.
  2. Physical Connection:
    • Modbus RTU: Modbus RTU typically uses two-wire or four-wire serial connections, allowing for multi-drop communication where multiple devices can be connected on the same bus.
    • Modbus TCP/IP: Modbus TCP/IP requires an Ethernet infrastructure with RJ45 connectors and twisted-pair or fiber optic cables. It utilizes standard Ethernet switches and routers for network connectivity.
  3. Data Transmission Format:
    • Modbus RTU: Modbus RTU uses binary encoding to represent data. It is a compact and efficient format that uses a smaller number of bytes for data transmission.
    • Modbus TCP/IP: Modbus TCP/IP encapsulates Modbus commands and data within TCP/IP packets, allowing for reliable transmission over Ethernet. It uses ASCII or hexadecimal encoding for textual representation of data.
  4. Network Size and Scalability:
    • Modbus RTU: Modbus RTU supports smaller network sizes due to the limitations of serial communication. It is commonly used in local networks with a limited number of devices.
    • Modbus TCP/IP: Modbus TCP/IP supports larger network sizes as it operates over Ethernet, which allows for more extensive network infrastructure and greater scalability. It can accommodate a higher number of devices spread across multiple locations.
  5. Speed and Throughput:
    • Modbus RTU: Modbus RTU operates at relatively lower baud rates, typically ranging from 1200 bps to 115.2 kbps. The speed depends on the serial connection and cable length.
    • Modbus TCP/IP: Modbus TCP/IP offers higher data rates as it takes advantage of Ethernet technology. It supports data rates of 10 Mbps, 100 Mbps, or even 1 Gbps, depending on the Ethernet infrastructure.
  6. Network Configuration and Troubleshooting:
    • Modbus RTU: Modbus RTU requires manual configuration of communication parameters, such as baud rate, parity, and stop bits, on each device. Troubleshooting often involves checking physical connections and serial communication settings.
    • Modbus TCP/IP: Modbus TCP/IP simplifies network configuration as it uses standard IP addressing and relies on Ethernet infrastructure. Troubleshooting can involve checking IP connectivity, network switches, and firewall settings.